RI Integra 3TM
Every detail of the RI Integra 3™ is geared towards one goal – to ensure you create the best possible conditions for ICSI and sample manipulation.
We recognise that temperature and time are critical within an ART lab. RI Integra 3™ is ultra-responsive and effortlessly smooth, so it’s quick and easy to use, thanks to RI’s advanced mechanical design. You can change micropipettes in seconds, which can transform the efficiency of your lab overnight.
We have increased the size of the integrated heated stage by 40% but kept the footprint to a minimum to keep your work area uncluttered.
Availability
This product is available for sale in the USA, Europe and the rest of the world.
Key Product Information
“By far the best new feature is the warm air flow through the central plate – which means your dish can maintain the correct temperature throughout the procedure. The egg counter feature has also been a blessing in large cases, as well as the warning “beeps” for the fine manipulator height indicator”
Sophie Bird MMedSci ClinSci DipRCPath, ACU Lab Manager, Epsom & St.Helier NHS
ThermosafeTM – Ultimate Thermal Control for RI Integra 3TM
Thermosafe™ is an integral heating system that helps to keep samples at the optimum temperature. It emits warm air precisely and uniformly towards the Petri dish.
The result of this is a fail-safe guarantee, with no more cold spots, no more hot spots and no more ambiguity.
There is also a stage temperature health indicator light to reassure you that the integrated heating system is functioning correctly.
Thermal image of Petri dish surface when placed on heated metal plate WITH THERMOSAFE™
Petri dish surface when placed on heated metal plate WITHOUT THERMOSAFE™
Petri dish surface when placed on market leading glass ITO WITHOUT THERMOSAFE™
Key Features
No Cold Spots
Thermosafe™ maintains sample temperature with a gentle stream of warm air under the Petri dish
Super-Fast
Improved rapid micropipette set-up with one-step angle adjustment
Practical
Motion sensor LED light underneath the stage for improved visibility when changing objectives
Safe
Heating system status indicator light and alarm monitors every second of the process. A log is kept of every alarm triggered
Integrated
Large built-in mechanical XY stage plus temperature controllers with easy access buttons and touch screen
Accurate
New extra-fine mechanisms for smooth and precise movement of the stage and micropipettes
Additional Functions and Features
Colour Touch Screen
Using the 3.5 inch touch screen display, you can check temperature, track time with a stop watch and count the number of injections done. The electronic height indicators track the vertical position of the tool holders.
Shortcut Video And Images
If you need to keep track of samples or procedures, just hit the shortcut buttons to film or photograph any stage of the process. There’s a counter button and an onscreen stopwatch as well.
Motion Triggered LED Light
A motion triggered light illuminates under the stage as soon as it detects your hand, to help you see when changing objectives.
Precise And Intuitive Control
When you perform ART micromanipulation procedures, accuracy is paramount. RI Integra 3™ offers the finest possible movement on the XYM stage and fine and coarse levers as well as a choice of oil or air syringes for the control of samples.
RI ViewerTM Software
You can use the RI Integra 3™ without a computer or camera. However, if you connect it to a computer, we can supply the RI Viewer™ software. With RI Viewer™ you can use the shortcut keys. Enjoy razor-sharp full screen imaging from the microscope, with digital magnification and a modern, clean user interface.
It also offers line measurement tools and a built-in simulator for training and demonstration purposes. RI Viewer™ also allows you to sync up with RI Saturn 5™ laser and RI IMSI™ systems.
Syringes
The RI Integra 3™ includes two of our SAS air syringes as standard. These syringes offer superb control and eliminate the need for oil. Also available is the SAS-SE for superfine air control or our SOS oil syringe with a quick fill feature for minimum set-up time.
Microscope Compatibility
NIKON
Ti2-U, and discontinued models: TMD, Diaphot 200/300 TE2000, TE200/300
OLYMPUS
IXPlore (IX73), and discontinued models: IMT2, IX50/70 IX51/71/81
LEICA
DMi8, and discontinued models: DMIRB, DMI3000B/4000B/6000B DM IL
ZEISS
Axio Observer, and discontinued models: Axiovert 40/100/200, Axio Vert.A1
Product Specifications
Heating System | Thermosafe™ Air Heating System with Heated Metal Insert: 25mm aperture (standard) 16mm aperture (optional) ITO Heated Glass Insert (optional) |
Temperature Controller | Accuracy: better than ±0.1ºC when calibrated against known reference Resolution: 0.1ºC Setpoint Temperature Range: 30-45ºC |
Display | 3.5″ colour LCD touch screen display for temperature control |
Connectivity | USB socket for connection to PC running RI Viewer™ software |
Syringes | Choice of SAS (air), SAS-SE (air) and SOS (oil) |
Weight | Maximum weight of microscope mounted components (excluding front and rear adaptors): 10.4kg Actual weight is configuration dependent |
Dimensions | Footprint (not including microscope): width 56cm, depth 38cm |
Power Supply | Input: 100-240VAC, 50-60HZ, Max. 1.8A, Class 1 Output: 12VDC, Min. 11A (132W) |
Operating Range | Temperature: 15ºC (59ºF) to 40ºC (104ºF) Humidity:15% to 85% RH (non condensing) |
Micropipette Compatibility | Compatible with CooperSurgical micropipettes (or other industry standard 1.0mm outside diameter micropipettes or equivalent specification). |
Order Codes
Please use the table below to select the correct part number for your equipment.
For Saturn Fixed , other microscopes and any other system not covered by the part numbers below, contact our Customer Service team in your region
Microscope Manufacturer | Model | Syringe Choice | Part Number | Description |
---|---|---|---|---|
Nikon | Ti2 | None | 6-54-100-14 | RI Integra 3 Thermosafe Nikon No Syringes |
Nikon | Ti2 | 2 x SAS | 6-54-100-15 | RI Integra 3 Thermosafe Nikon 2 x SAS |
Nikon | Ti2 | 1 x SAS, 1 x SAS-SE |
6-54-100-16 | RI Integra 3 Thermosafe Nikon 1 x SAS 1 x SAS-SE |
Nikon | Ti2 | 2 x SAS-SE | 6-54-100-17 | RI Integra 3 Thermosafe Nikon 2 x SAS-SE |
Nikon | Ti-S, Ti-U, Ti-E TE2000,TE200, TE300 |
None | 6-54-100-01 | RI Integra 3 Thermosafe Nikon No Syringes |
Nikon | Ti-S, Ti-U, Ti-E,TE2000,TE200, TE300 | 2 x SAS | 6-54-100-02 | RI Integra 3 Thermosafe Nikon 2 x SAS |
Nikon | Ti-S, Ti-U, Ti-E,TE2000,TE200, TE300 | 1 x SAS, 1 x SAS-SE |
6-54-100-03 | RI Integra 3 Thermosafe Nikon 1 x SAS , 1 x SAS-SE |
Nikon | Ti-S, Ti-U, Ti-E,TE2000,TE200, TE300 | 2 x SAS-SE | 6-54-100-04 | RI Integra 3 Thermosafe Nikon 2 x SAS-SE |
Olympus | IX53, IX73, IX83,IX51, IX71, IX81 | None | 6-54-100-05 | RI Integra 3 Thermosafe Olympus No Syringes |
Olympus | IX53, IX73, IX83,IX51, IX71, IX81 | 2 x SAS | 6-54-100-06 | RI Integra 3 Thermosafe Olympus 2 x SAS |
Olympus | IX53, IX73, IX83,IX51, IX71, IX81 | 1 x SAS, 1 x SAS-SE |
6-54-100-07 | RI Integra 3 Thermosafe Olympus 1 x SAS, 1 x SAS-SE |
Olympus | IX53, IX73, IX83,IX51, IX71, IX81 | 2 x SAS-SE | 6-54-100-08 | RI Integra 3 Thermosafe Olympus 2 x SAS-SE |
Olympus | IX50, IX70 | 2 x SAS | 6-54-100-13 | RI Integra 3 Thermosafe Olympus IX1 2 x SAS |
Olympus | IX1 Series | None | 6-54-100-18 | RI Integra 3 Thermosafe Olympus IX1 No Syringes |
Leica | DMi8, DMIx000B, DMIRB | None | 6-54-100-09 | RI Integra 3 Thermosafe Leica No Syringes |
Leica | DMi8, DMIx000B, DMIRB | 2 x SAS | 6-54-100-10 | RI Integra 3 Thermosafe Leica 2 x SAS |
Leica | DMi8, DMIx000B, DMIRB | 1 x SAS, 1 x SAS-SE |
6-54-100-11 | RI Integra 3 Thermosafe Leica 1 x SAS, 1 x SAS-SE |
Leica | DMi8, DMIx000B, DMIRB | 2 x SAS-SE | 6-54-100-12 | RI Integra 3 Thermosafe Leica 2 x SAS-SE |
Leica | DMi8, DMIx000B, DMIRB | 2 x SAS | 6-54-110-01 | RI Integra 3 No Thermosafe Leica 2 x SAS |
Leica | DMi8, DMIx000B, DMIRB | 2 x SAS | 6-54-110-12 | RI Integra 3 ITO Leica 2 x SAS |